Large Display

  • The Trident PD765 digital panel meter is one of the most versatile meters on the market and will satisfy a wide variety of process and temperature applications. Housed in an 1/8 DIN enclosure with a NEMA 4X front, the meter can be field programmed to accept process voltage (0-5 V, 1-5 V, etc.) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. The display height on the standard Trident meter is 0.56" (14.2 mm) and on the Trident X2 the display height is an astounding 1.2" (30.5 mm). The intensity of the display can be adjusted to compensate for various lighting conditions, including direct sunlight. Programming and setup can be performed with the four front panel pushbuttons, free MeterView software, or using the copy function. Options for the PD765 include 2 relays, a 4-20 mA output, 24 V transmitter power supply, and Modbus® serial communications.

    PD765 X2
    Why you should buy:
    • Big Display
    • 1/8 DIN Panel Meter
    • Universal Inputs
    • 2 Relays & 4-20 mA Output
  • Go with the Helios PD2-6000 when you need a large display meter to display the 4-20 ma output from any transmitter you might have. The PD2-6000 can display that output in six full digits and will also provide the 24 VDC to power the transmitter. The PD2-6000's NEMA 4X enclosure, super bright, 1.8" (46 mm) high LEDs, and wide operating temperature range make it perfect for outdoor applications. The PD2-6000 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or control applications, including pump alternation control.




    Why you should buy:
  • The PD685 is an ATEX and IECEx intrinsically safe, IP67 loop-powered indicator that is easy to install and program and can be seen from considerable distance. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The meter gets all of the power it needs from the 4-20 mA loop and its 1 V (4 V with backlight) drop results in a minimal burden on the loop. The meter features a wide -40°C to +75°C operating temperature range and is available with a 22 mm (0.865") conduit hole in a location of your choice for easy installation. Calibration is a quick two-step process involving the adjustment of only two sets of coarse and fine, non-interacting potentiometers.


    Why you should buy:
  • The PD686 is an Intrinsically Safe and Nonincendive, NEMA 4X, loop-powered indicator that is easy to install and program and can be seen from considerable distance. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area; the meter gets all of the power it needs from the 4-20 mA loop and the PD686's 1 V drop results in a minimal burden on the loop. The meter features FM and CSA approvals as Intrinsically Safe and Nonincendive, a wide -40 to 85°C operating temperature range, and is provided with a ½" conduit hole in a location of your choice for easy installation. Calibration is a quick two-step process involving the adjustment of only two non-interacting potentiometers.

    Why you should buy:
  • The Vantageview PD6770 is a plastic, loop-powered process meter with 1" display digits in a field-mountable enclosure designed for demanding applications. The meter derives all of its power from the 4-20 mA loop with a small 1 V drop, so there is no need to run additional, costly power lines. The PD6770 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It is programmed using four easy-to-access, front-mounted control dials.




    Why you should buy:
    • NEMA 4X/IP65 Enclosure
    • Loop-Powered
    • Large Digits
    • Backlight Option
  • The ProtEX FarVu PD6870 is an explosion-proof, loop-powered process meter with 1" display digits in a field-mountable enclosure designed for demanding applications in hazardous areas or in the harshest environmental conditions. The meter derives all of its power from the 4-20 mA loop with a small 1 V drop so there is no need to run additional, costly power lines into a hazardous area. Like all ProtEX products, the PD6870 loop-powered indicator carries FM, CSA, ATEX, and IECEx approvals for use in hazardous areas. It is programmed using four easy-to-access, front-mounted control dials.




    Why you should buy:
  • Go with the Helios PD2-6001 when you prefer to read level in feet and inches instead of the more common decimal format. This unique display will read up to 99 feet, 11 & 15/16s inches on the upper line. The lower line can display a tag or volume, even from non-linear tanks such as round horizontal ones. The PD2-6001 makes a great outdoor tank side indicator because its display is bright enough to read in direct sunlight and it will operate from -40 to 150°F. The PD2-6001 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or controlling applications, including pump alternation control.



    Why you should buy:
  • Go with the Helios PD2-6060 when you need a large display meter to display two 4-20 mA inputs on one meter. Both of these inputs can be displayed on six full digits and each transmitter is provided with its own 24 VDC transmitter power supply. The PD2-6060 can also perform a variety of math functions on those two inputs, such as computing the difference between them or summing them together.

     

     

     

    Why you should buy:
  • Go with the Helios PD2-6080 when you have multiple, (up to 16), Modbus registers you want to display on a single large display meter. The PD2-6080 can also accept two 4-20 mA signals. The PD2-6080 can be programmed as a Modbus RTU Master, Slave or Snooper allowing it to work in just about any Modbus application. Typically, the upper line displays the PV and the lower line displays the tag.

     

     

     

     

    Why you should buy:
  • Go with the Helios PD2-6081 when you have a level application involving Modbus signals and you prefer to display in feet and inches instead of the more common decimal format. The PD2-6081 can display up to 16 modbus registers so a typical application might be 16 tank levels, 8 tank levels and 8 interface levels, or 5 tank levels, 5 interface levels and 5 temperatures. The PD2-6081 makes a great outdoor tank side indicator because its display is bright enough to read in direct sunlight and it will operate from -40 to 150°F.

     

     

     

    Why you should buy: