Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

Two 4-20 mA Outputs Dual-Line Display

Displaying 10 total products (page 1 of 1):

  • The PD6060 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts two inputs of either a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal. It displays these signals on a dual line, 6-digit display that is available with an optional Sunbright® sunlight readable LEDs. The meter can be customized such that these two inputs are displayed in a variety of ways, including both at the same time with tags or the result of math functions performed on one or both of the inputs. Like all ProVu meters, the PD6060 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. The PD6060 can also be equipped with up to four internal relays, a 4-20 mA analog output, and Modbus® serial communications. The PD6060 includes a 24 V DC power supply to drive the transmitters. ProVu meters can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The ProVu PD6080 Super Snooper Modbus® scanner is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and accepts two analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of an easy-to-read and conveniently located remote display. As a master, the PD6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the PD6080 can read any Modbus variable being polled by a master, which allows you to easily add a display into an existing Modbus network. Like all ProVu meters, the PD6080 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6081 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The PD6081 can be setup as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6081 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6088 Super Snooper Modbus® scanner displays up to 16 Modbus process variables (PVs) on the bus using its RS-485 serial input. The PD6088 can function as a Modbus master, slave, or snooper. As a Modbus master, the PD6088 can poll multiple Modbus devices for up to 16 Modbus process variables. As a slave, a Modbus master can write up to 16 PVs to the scanner for display. In snooper mode, it can sit anywhere on the Modbus network and display up to 16 PVs being polled on the bus. When connecting a scanner in snooper mode, no other Modbus devices on the network need to be reconfigured, making it easy to add additional local or remote displays to a Modbus network. Like all ProVu meters, the PD6088 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6089 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6089 can function as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6089 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The PD6262 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) analog output (4-20 mA, 0-5 V, 1-5 V, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6262 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6262 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The PD6363 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6363 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6363 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The PD6400 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts a high voltage (0-300 VAC/VDC) and high current (0-5 AAC/ADC) input simultaneously. It is ideal for measuring direct voltage and current or the output from voltage shunts and current transformers. It displays the input on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The high voltage and current meter can be customized to display the voltage on one line and the current on the other or to display the apparent power by multiplying the two inputs. Like all ProVu meters, the PD6400 AC/DC voltage and current meter includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output and Modbus® RTU serial communications.

    Why you should buy:
    • High Current and High Voltage Inputs
    • Calculate Apparent Power
    • USB Programming
  • The Nova PD540 is a digital temperature controller with auto-tuning PID capabilities that is available in 1/16, 3/16, 1/8, and 1/4 DIN sizes. Models include standard one-directional control (i.e. heating or cooling) or bi-directional heating and cooling control. One of four user programmable set points may be selected for PID control in the form of time proportional relay on/off output, time proportional voltage pulse output, or 4-20 mA signal control. Its universal input accepts 23 input varieties, including thermocouple, RTD, and voltage inputs, and it can be easily configured for a 4-20 mA input. It is available with up to three (3) relays, two (2) 4-20 mA analog outputs, two (2) digital inputs, and an RS485 serial communication option which includes protocols for master/slave set point control, Modbus® ASCII and RTU, as well as PC software.

    Why you should buy:
    • Auto-Tuning PID Controller
    • Temperature and Process Inputs
    • Heating & Cooling
  • The Nova PD550 is a digital temperature controller with two ramp and soak programs capable of storing 15 segments each for precision PID set point control. It is available in 1/16, 3/16, 1/8, and 1/4 DIN sizes. At the completion of a program, the controller can hold the set point, stop the outputs, or loop to one of the 30-segment programs. Its universal input accepts 23 input varieties, including thermocouple, RTD, and voltage inputs, and it can be easily configured for a 4-20 mA input. It is available with up to three (3) relays, two (2) 4-20 mA analog outputs, four (4) digital inputs, and an RS485 serial communication option which includes protocols for master/slave set point control, Modbus® ASCII and RTU, as well as PC software.



    Why you should buy:
    • Two Ramp & Soak Programs
    • Auto-Tuning PID
    • Temperature and Process Inputs