Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

Totalizer Loop-Power

Displaying 6 total products (page 1 of 1):

  • The Loop Leader PD6620 is a loop-powered, 1/8 DIN flow rate/totalizer designed for demanding process control applications. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6624) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered rate/totalizer is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 167°F (-40 to 75°C) operating temperature range. It doesn't matter if it's indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.



    PD6622
    Why you should buy:
  • The Loop Leader PD6620 is an ATEX and IECEx approved, UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN flow rate/totalizer designed for demanding process control applications. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6628) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered rate/totalizer is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's in hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6626
    Why you should buy:
  • The Loop Leader PD684 is a loop-powered, 1/8 DIN flow rate/totalizer designed for demanding process control applications. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The PD684 loop-powered rate/totalizer is built in a shallow-depth case with an FM Type 4X front and features loop-powered backlighting and a wide -30 to 65°C operating temperature range. It doesn't matter if it's indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

     

    Why you should buy:
    • Loop-Powered
    • 1/8 DIN Panel Mount
    • NEMA 4X/IP65 Front
    • Rate/Totalizer
  • The Loop Leader PD689 is an Intrinsically Safe and Nonincendive, loop-powered, 1/8 DIN flow rate/totalizer designed for hazardous process control applications. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area; the meter gets all of the power it needs from the 4-20 mA loop. The PD689 loop-powered rate/totalizer is built in a shallow-depth case with an FM Type 4X front and features loop-powered backlighting and a wide -30 to 65°C operating temperature range. It doesn't matter if it's indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere. The PD689 can be installed in just about any hazardous area environment under the FM, CSA, and ATEX standards.

    Why you should buy:
  • The Vantageview PD6720 is a plastic, field-mounted, loop-powered flow rate/totalizer that can display flow rate and total from an analog output (4-20 mA) flowmeter. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines. The display has a five digit upper display for rate, a seven alpha-numeric character lower display for total, and comes standard with a backlight. The PD6720 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. Two features that really make it stand out are a wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the PD6720 to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

    Why you should buy:
  • The ProtEX-RTA PD6820 is an explosion-proof, loop-powered flow rate/totalizer that can display flow rate and total from an analog output (4-20 mA) flowmeter. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The display has a five digit upper display for rate, a seven alpha-numeric character lower display for total, and comes standard with a backlight. Like all ProtEX products, the PD6820 explosion-proof flow rate/totalizer carries FM, CSA, ATEX, and IECEx approvals for use in hazardous areas. Two features that really make this flow rate/totalizer stand out are a wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6820 to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.