Level Pressure UL/C-UL

Level
Level is one of the most common applications for Precision Digital’s meters. Our most popular products can be used for level applications and we also have meters that are specifically intended for use in level systems. These digital panel meters and explosion-proof indicators communicate critical level information at eye-level to the operator, effectively increasing safety by eliminating the need for operators to climb the tanks. The level can also be controlled with the use of relays, open collector, or 4-20 mA analog outputs. Select products include specialized level features such as pump alternation control, unique feet & inches displays with clearly labeled units, and dual-scale level displays that show level in two units from a single transmitter signal.

Level Pressure UL/C-UL

  • The Trident PD765 digital panel meter is one of the most versatile meters on the market and will satisfy a wide variety of process and temperature applications. Housed in an 1/8 DIN enclosure with a NEMA 4X front, the meter can be field programmed to accept process voltage (0-5 V, 1-5 V, etc.) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. The display height on the standard Trident meter is 0.56" (14.2 mm) and on the Trident X2 the display height is an astounding 1.2" (30.5 mm). The intensity of the display can be adjusted to compensate for various lighting conditions, including direct sunlight. Programming and setup can be performed with the four front panel pushbuttons, free MeterView software, or using the copy function. Options for the PD765 include 2 relays, a 4-20 mA output, 24 V transmitter power supply, and Modbus® serial communications.

    PD765 X2
    Why you should buy:
    • Big Display
    • 1/8 DIN Panel Meter
    • Universal Inputs
    • 2 Relays & 4-20 mA Output
  • The PD6000 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal. It displays that signal on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. Like all ProVu meters, the PD6000 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output and Modbus® RTU serial communications. The PD6000 includes a 24 VDC power supply to drive the transmitter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.



    Why you should buy:
  • Go with the Helios PD2-6000 when you need a large display meter to display the 4-20 ma output from any transmitter you might have. The PD2-6000 can display that output in six full digits and will also provide the 24 VDC to power the transmitter. The PD2-6000's NEMA 4X enclosure, super bright, 1.8" (46 mm) high LEDs, and wide operating temperature range make it perfect for outdoor applications. The PD2-6000 can also be equipped with a 4-20 mA output as well as four relays that can be used for alarming or control applications, including pump alternation control.




    Why you should buy:
  • The Loop Leader PD6600 is an ATEX, IECEx approved, and UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6608) or feet & inches display (PD6607) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6606
    Why you should buy:
  • The PD6060 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts two inputs of either a process current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal. It displays these signals on a dual line, 6-digit display that is available with an optional Sunbright® sunlight readable LEDs. The meter can be customized such that these two inputs are displayed in a variety of ways, including both at the same time with tags or the result of math functions performed on one or both of the inputs. Like all ProVu meters, the PD6060 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. The PD6060 can also be equipped with up to four internal relays, a 4-20 mA analog output, and Modbus® serial communications. The PD6060 includes a 24 V DC power supply to drive the transmitters. ProVu meters can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • Go with the Helios PD2-6060 when you need a large display meter to display two 4-20 mA inputs on one meter. Both of these inputs can be displayed on six full digits and each transmitter is provided with its own 24 VDC transmitter power supply. The PD2-6060 can also perform a variety of math functions on those two inputs, such as computing the difference between them or summing them together.

     

     

     

    Why you should buy:
  • The Sabre P PD603 process meter combines operational simplicity with high end features to deliver the perfect low-cost 1/8 DIN digital panel meter for display only applications. The PD603’s menu structure is easy to navigate because the only selections are for input, decimal point location, and scaling values; there are no other menu choices to add confusion during the setup process. Despite being a low-cost meter, the PD603 is still packed with many features typically found only on more expensive meters, such as a NEMA 4X front, universal power supply, front panel programming, input current overload protection, UL listing, and CE marking.


    Why you should buy:
    • Low Cost Display Only Option
    • NEMA 4X/IP65 Front
    • Analog Input
  • The ProVu PD6080 Super Snooper Modbus® scanner is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and accepts two analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of an easy-to-read and conveniently located remote display. As a master, the PD6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the PD6080 can read any Modbus variable being polled by a master, which allows you to easily add a display into an existing Modbus network. Like all ProVu meters, the PD6080 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6081 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The PD6081 can be setup as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6081 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy: