Sunlight Readable LCD

  • The Loop Leader PD6600 is a general-purpose, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6604) or feet & inches display (PD6603) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 167°F (-40 to 75°C) operating temperature range. It doesn't matter if it's indoors or out-doors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.


    Why you should buy:
  • The ProtEX-Pro PD6800 is one of Precision Digital's most advanced and feature-packed explosion-proof, loop-powered indicators. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. Like all ProtEX products, the PD6800 carries CSA, ATEX, and IECEx approvals for use in hazardous areas. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. The display has a five digit upper display, a seven alpha-numeric character lower display, and is available with a twenty-segment bar graph for level applications. Two features that really make the PD6800 stand out are its wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6800 to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.

    Aluminum or Stainless Steel
  • The Loop Leader PD6600 is an ATEX, IECEx approved, and UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6608) or feet & inches display (PD6607) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6606
    Why you should buy:
  • The Loop Leader+ loop-powered large display flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their large, dual-line display which is typically used to display flow rate on the 2.8" 5-character alphanumeric top display and flow total, flow grand total, or a tag on the 1.5" 8-character alphanumeric bottom display. Both display lines use 14-segment, alphanumeric characters that provide much clearer indication of tags, units, or alarm messages than 7-segment characters do.

    Further enhancing the display on these instruments is a 20-segment bargraph that also includes a numeric value of the percentage the bargraph represents. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    The PD4 is available in two configurations: Display only and with two solid-state relays and 4-20 mA analog output. All models come equipped with two open collector outputs and remote contacts. The open collector outputs are useful for alarm indication or pulse output. The remote contacts can be used to remotely operate the four programming buttons, to reset the total, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

    Finally, the PD4-6628 is an intrinsically safe version that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Display Rate & Total Simultaneously
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Discrete and Analog Output Options
  • The Loop Leader+ loop-powered large display flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their large, dual-line display which is typically used to display flow rate on the 2.8" 5-character alphanumeric top display and flow total, flow grand total, or a tag on the 1.5" 8-character alphanumeric bottom display. Both display lines use 14-segment, alphanumeric characters that provide much clearer indication of tags, units, or alarm messages than 7-segment characters do.

    Further enhancing the display on these instruments is a 20-segment bargraph that also includes a numeric value of the percentage the bargraph represents. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    The PD4 is available in two configurations: Display only and with two solid-state relays and 4-20 mA analog output. All models come equipped with two open collector outputs and remote contacts. The open collector outputs are useful for alarm indication or pulse output. The remote contacts can be used to remotely operate the four programming buttons, to reset the total, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

    Finally, the PD4-6628 is an intrinsically safe version that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Display Rate & Total Simultaneously
    • Intrinsically Safe
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Discrete and Analog Output Options
  • The ProtEX+ loop-powered explosion-proof & intrinsically safe meters can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the process variable on the 5-character alphanumeric top display and the units of measure or tag on the 8-character alphanumeric bottom display. Feet and inches models display level in feet and inches on the top display while the 8-digit alphanumeric bottom line may be used to display a tag or custom message. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ Series is CSA Certified as Explosion-Proof / Dust-Ignition Proof / Flame-Proof and ATEX and IECEx Certified as Intrinsically Safe. Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options
  • The ProtEX+ loop-powered explosion-proof & intrinsically safe flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the flow rate on the 5-character alphanumeric top display and flow total, flow grand total, or tag on the 8-character alphanumeric bottom display. The top display uses 12-segment, and the bottom display uses 14-segment alphanumeric characters for clear indication of tags, units, or alarm messages. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ Series is CSA Certified as Explosion-Proof / Dust-Ignition Proof / Flame-Proof and ATEX and IECEx Certified as Intrinsically Safe.

    Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered Rate / Totalizer
    • Display Rate & Total Simultaneously
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Discrete and Analog Output Options
  • The PD663 is a loop-powered field meter that is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 connections. The PD663 is easy to install and program and it can be seen in a variety of lighting conditions, even in bright sunlight. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however the display will cease functioning.


  • The Vantageview PD6700 is one of Precision Digital's most advanced and feature-packed plastic, field-mounted, loop-powered indicators. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines. The PD6700 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. The display has a five digit upper display, a seven alpha-numeric character lower display, and comes with a backlight standard. Two features that really make the PD6700 stand out are its wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the meter to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

    Why you should buy:
    • NEMA 4X/IP65 Enclosure
    • Loop-Powered
    • Level Indication Bargraph Display
  • The PD6908-GP loop-powered process meter and PD6907-GP feet & inches level meter include a NEMA 4X, IP66 plastic enclosure and can be installed in a variety of harsh operating environments to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their dual-line display which is typically used to display the process variable on the 5-character alphanumeric top display and the units of measure or a tag on the 8-character alphanumeric bottom display. The feet & inches models display level in feet and inches on the top display and the bottom 8-character alphanumeric display can be used to display a tag or custom message.

    The VantageView+'s 14-segment alphanumeric characters on the bottom display line provide a much clearer indication of tags, units, or alarm messages than 7-segment characters do.

    Further enhancing the display on these instruments is a 20-segment bargraph.

    The four CapTouch through-window buttons located on the front of the meter provide a convenient way to operate the meter without removing the cover.

    Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered
    • Plastic NEMA 4X Enclosure
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options