LCD

  • The Loop Leader PD6600 is a general-purpose, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6604) or feet & inches display (PD6603) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 167°F (-40 to 75°C) operating temperature range. It doesn't matter if it's indoors or out-doors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.


    Why you should buy:
  • The Loop Leader PD6600 is an ATEX, IECEx approved, and UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6608) or feet & inches display (PD6607) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6606
    Why you should buy:
  • The SuperNova PD500 Series of PID Process & Temperature Controllers is a complete line of PID and on/off controllers. Available in popular 1/4, 1/8, and 1/16 DIN sizes, and with a shallow depth behind panel of only 2.5" (63 mm) it is easy to fit into almost any panel, product, or enclosure. Voltage, current (with external resistor), and direct temperature thermocouple and RTD inputs make it an excellent choice for any control application requiring easy to change, visible set points. This modern line of controllers shows the process variable (PV), set value (SV), and manipulated value (output level%, MV) on a striking reverse polarity LCD screen. Indicators for units (˚C, ˚F,%, or none) Auto and manual control modes can be easily changed by holding two buttons, and this is indicated on the front panel to make it easy for operators to know how to use this feature. Main control outputs can be 4-20 mA (SCR), voltage pulse (SSR), or relay outputs. A secondary relay control output is standard, which allow for one or two direction SV control (i.e., heating and cooling). Additional outputs may include two SPST alarm relays and a 4-20 mA retransmit output. Other options include a secondary 4-20 mA input to remotely control the set point, and RS-485 for Modbus communication. A mini-USB port may be used for a direct PC connection to run the SuperNova software for monitoring, programming, and data logging. This USB port is located on the rear behind the panel for PD510 1/16 DIN models, and on the front behind a rubber tab on PD520 and PD530 1/8 and 1/4 DIN models.
    Why you should buy:
    • Auto-Tuning PID Controller
    • Temperature and Process Inputs
    • Heating & Cooling
  • The Loop Leader+ loop-powered large display meters can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their large, dual line display. The 2.8" 5-digit top display is used to display the process variable while the 1.5" 8-character alphanumeric bottom display can be used to display the units of measure or a tag. Feet and inches models display level in feet and inches on the top display while the 8-digit alphanumeric bottom line may be used to display a tag or custom message.

    Further enhancing the display on these instruments is a 20-segment bargraph that also includes a numeric value of the percentage the bargraph represents. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    The PD4 is available in two configurations: Display only and with two solid-state relays and 4-20 mA analog output. All models come equipped with two open collector outputs and remote contacts. The open collector outputs are useful for alarm indication. The remote contacts can be used to remotely operate the four programming buttons, to acknowledge the relays, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, on/off control, or pump alternation.

    Finally, there are intrinsically safe versions of these instruments that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options
  • The Loop Leader+ loop-powered large display meters
    can be installed virtually anywhere to provide convenient
    and informative display of any 4-20 mA signal. One of
    the most convenient features of these instruments is their
    large, dual line display. The 2.8" 5-digit top display is used
    to display the process variable while the 1.5" 8-character
    alphanumeric bottom display can be used to display the
    units of measure or a tag. Feet and inches models display
    level in feet and inches on the top display while the 8-digit
    alphanumeric bottom line may be used to display a tag or
    custom message.

    Further enhancing the display on these instruments is a
    20-segment bargraph that also includes a numeric value of
    the percentage the bargraph represents.
    Free, PC-based, MeterView XL software that connects
    to the meter via a micro USB cable is available for
    programming and setup of the meters.

    The PD4 is available in two configurations: Display only
    and with two solid-state relays and 4-20 mA analog output.
    All models come equipped with two open collector outputs
    and remote contacts. The open collector outputs are
    useful for alarm indication. The remote contacts can be
    used to remotely operate the four programming buttons, to
    acknowledge the relays, to start/stop a timer/stopwatch, and
    more. The relays can be programmed for alarm indication,
    on/off control, or pump alternation.

    Finally, there are intrinsically safe versions of these
    instruments that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Intrinsically Safe
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options
  • The Loop Leader+ loop-powered large display flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their large, dual-line display which is typically used to display flow rate on the 2.8" 5-character alphanumeric top display and flow total, flow grand total, or a tag on the 1.5" 8-character alphanumeric bottom display. Both display lines use 14-segment, alphanumeric characters that provide much clearer indication of tags, units, or alarm messages than 7-segment characters do.

    Further enhancing the display on these instruments is a 20-segment bargraph that also includes a numeric value of the percentage the bargraph represents. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    The PD4 is available in two configurations: Display only and with two solid-state relays and 4-20 mA analog output. All models come equipped with two open collector outputs and remote contacts. The open collector outputs are useful for alarm indication or pulse output. The remote contacts can be used to remotely operate the four programming buttons, to reset the total, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

    Finally, the PD4-6628 is an intrinsically safe version that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Display Rate & Total Simultaneously
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Discrete and Analog Output Options
  • The Loop Leader+ loop-powered large display flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. One of the most convenient features of these instruments is their large, dual-line display which is typically used to display flow rate on the 2.8" 5-character alphanumeric top display and flow total, flow grand total, or a tag on the 1.5" 8-character alphanumeric bottom display. Both display lines use 14-segment, alphanumeric characters that provide much clearer indication of tags, units, or alarm messages than 7-segment characters do.

    Further enhancing the display on these instruments is a 20-segment bargraph that also includes a numeric value of the percentage the bargraph represents. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    The PD4 is available in two configurations: Display only and with two solid-state relays and 4-20 mA analog output. All models come equipped with two open collector outputs and remote contacts. The open collector outputs are useful for alarm indication or pulse output. The remote contacts can be used to remotely operate the four programming buttons, to reset the total, to start/stop a timer/stopwatch, and more. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

    Finally, the PD4-6628 is an intrinsically safe version that can be installed in hazardous areas.

    Why you should buy:
    • 2.8" Dual-Line Backlit LCD Display
    • Loop-Powered
    • Display Rate & Total Simultaneously
    • Intrinsically Safe
    • Flashing Red Display / Message on Alarm
    • Free Programming Software
    • Discrete and Analog Output Options
  • The ProtEX+ loop-powered explosion-proof & intrinsically safe meters can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the process variable on the 5-character alphanumeric top display and the units of measure or tag on the 8-character alphanumeric bottom display. Feet and inches models display level in feet and inches on the top display while the 8-digit alphanumeric bottom line may be used to display a tag or custom message. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ carries all major approvals including:

    •  UL Listed as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  CSA Certified as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  ATEX and IECEx Certified as Intrinsically Safe / Explosion-Proof

    Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Bargraph or Feet & Inches Display
    • Discrete and Analog Output Options
  • The ProtEX+ loop-powered explosion-proof & intrinsically safe flow rate/totalizers can be installed virtually anywhere to provide convenient and informative display of any 4-20 mA signal. They can operate down to -40°C and be installed in areas that get as cold as -55°C, however the display will cease functioning. One of the most convenient features is the dual-line display, typically used to display the flow rate on the 5-character alphanumeric top display and flow total, flow grand total, or tag on the 8-character alphanumeric bottom display. The top display uses 12-segment, and the bottom display uses 14-segment alphanumeric characters for clear indication of tags, units, or alarm messages. Further enhancing the display on these instruments is a 20-segment bargraph.

    The ProtEX+ carries all major approvals including:

    •  UL Listed as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  CSA Certified as Explosion-Proof / Dust Ignition-Proof / Flame-Proof
    •  ATEX and IECEx Certified as Intrinsically Safe / Explosion-Proof

    Four CapTouch through-glass buttons are available to operate the instrument without removing the cover. Free, PC-based, MeterView XL software that connects to the meter via a micro USB cable is available for programming and setup of the meters.

    All models come equipped with two open collector outputs and a digital input. There are also models available with two solid-state relays and isolated 4-20 mA analog output options. The relays can be programmed for alarm indication, sample, timer, batch control, or stopwatch.

     

     

     

     

    Why you should buy:
    • Dual-Line Backlit LCD Display
    • Operate to -40°C; Install to -55°C
    • Loop-Powered Rate / Totalizer
    • Display Rate & Total Simultaneously
    • Explosion-Proof & Intrinsically Safe
    • Aluminum & Stainless Steel Enclosures
    • Flashing Red Display / Message on Alarm
    • CapTouch Through-Window Programming
    • 1.5 Volt Drop
    • Free Programming Software
    • Discrete and Analog Output Options
  • The Vantageview PD6700 is one of Precision Digital's most advanced and feature-packed plastic, field-mounted, loop-powered indicators. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines. The PD6700 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. The display has a five digit upper display, a seven alpha-numeric character lower display, and comes with a backlight standard. Two features that really make the PD6700 stand out are its wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the meter to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.

    Why you should buy:
    • NEMA 4X/IP65 Enclosure
    • Loop-Powered
    • Level Indication Bargraph Display