Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

2 24 VDC Power Supplies Sunlight Readable Display LED

Displaying 44 total products (page 3 of 5):

  • The PD6363 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6363 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6363 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The ProtEX-MAX PD8-6080 Super Snooper Modbus scanner offers all the functionality of the ProVu PD6080 as a CSA, ATEX, and IECEx certified explosion-proof product. It is available in an aluminum or stainless steel enclosure and will operate over a wide temperature range of -55 to 65°C (-67 to 149°F). It is a multi-purpose display and controller capable of scanning up to 16 process variables and includes dual analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of a conveniently located display in a hazardous area. As a master, the PD8-6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the scanner can read any Modbus variables being polled by a master, which allows you to easily add a display into an existing Modbus network. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio. The PD8-6080 can be equipped with four internal relays and a 4-20 mA output. It can be programmed and operated without opening the housing by using the built-in CapTouch through-glass buttons.

  • The ProtEX-MAX PD8-6081 Super Snooper feet & inches Modbus scanner offers all the functionality of the ProVu PD6081 as a CSA, ATEX, and IECEx certified explosion-proof product. It is available in an aluminum or stainless steel enclosure and will operate over a wide temperature range of -55 to 65°C (-67 to 149°F). It displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for hazardous areas with Modbus level or multivariable transmitters and is capable of scanning up to 16 process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD8-6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The scanner can be setup as a Modbus master, slave, or snooper. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio. The PD8-6081 can be equipped with four internal relays and a 4-20 mA output. It can be programmed and operated without opening the housing by using the built-in CapTouch through-glass buttons.

    Why you should buy:
  • The ProtEX-MAX PD8-6210 offers all the functionality of the ProVu PD6210 as a CSA, ATEX, and IECEx certified explosion-proof product. It is available in an aluminum or stainless steel enclosure and will operate over a wide temperature range of -55 to 65°C (-67 to 149°F). It is an analog input (4-20 mA, 0-5 V, 1-5 V, etc.) digital batch controller specifically designed for single and multi-stage batching applications. It provides excellent but simple batch control capabilities with features such as preclose relays and automatic overrun correction for more accurate batches and convenient CapTouch through-glass buttons for simple operation and menu navigation without having to remove the cover. The preclose deactivates a specific relay before the batch is finished in order to allow slower fill rates and increased accuracy. Automatic overrun correction keeps the batch size accurate over time and with system wear. The PD8-6210 includes a 24 VDC power supply to drive the flowmeter and can be equipped with four internal relays and a 4-20 mA analog output.

    Why you should buy:
  • Go with the Helios PD2-6310 when you need to do batch controlling using a pulse output flowmeter. The PD2-6310's huge display means operators don't have to be close up to the instrument to monitor the status of the batching application. And its NEMA 4X enclosure allows the PD2-6310 to be mounted in wet, dusty, and dirty areas. The PD2-6310 can handle single and multi-stage batching applications.

     

     

     

     

     

    Why you should buy:
    • Large Dual Line Display
    • Single or Multi-Stage Batching
    • Pulse Input
  • The ProVu PD6088 Super Snooper Modbus® scanner displays up to 16 Modbus process variables (PVs) on the bus using its RS-485 serial input. The PD6088 can function as a Modbus master, slave, or snooper. As a Modbus master, the PD6088 can poll multiple Modbus devices for up to 16 Modbus process variables. As a slave, a Modbus master can write up to 16 PVs to the scanner for display. In snooper mode, it can sit anywhere on the Modbus network and display up to 16 PVs being polled on the bus. When connecting a scanner in snooper mode, no other Modbus devices on the network need to be reconfigured, making it easy to add additional local or remote displays to a Modbus network. Like all ProVu meters, the PD6088 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6080 Super Snooper Modbus® scanner is a multi-purpose display and controller capable of scanning up to 16 Modbus process variables and accepts two analog process inputs. The scanner can be programmed as a Modbus RTU master, slave, or snooper. It is the ideal display for Modbus multivariable transmitters or for existing Modbus networks with transmitters in need of an easy-to-read and conveniently located remote display. As a master, the PD6080 can read up to 16 Modbus registers on up to 16 Modbus devices and automatically alternate each of these process variables (PVs) on the dual-line display along with a unit and tag for each. In snooper mode, the PD6080 can read any Modbus variable being polled by a master, which allows you to easily add a display into an existing Modbus network. Like all ProVu meters, the PD6080 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Powerful math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProVu PD6081 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6081 also has dual analog inputs, for integrating traditional 4-20 mA or voltage inputs in the display scanning. The PD6081 can be setup as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6081 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The ProtEX-MAX PD8-6300 offers all the functionality of the ProVu PD6300 as a CSA, ATEX, and IECEx certified explosion-proof product. It is available in an aluminum or stainless steel enclosure and will operate over a wide temperature range of -55 to 65°C (-67 to 149°F). It is specifically designed to display flow rate and total from a pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeter. It displays that signal on a dual-line, 6-digit Sunbright sunlight readable display. Flow rate is typically displayed on the upper line and the cumulative total is displayed on the lower line. The total overflow feature allows up to a 9-digit total and grand total to be displayed. The PD8-6300 includes a 24 VDC power supply to drive the flowmeter and can be equipped with four internal relays and a 4-20 mA analog output. It can be programmed and operated without opening the housing by using the built-in CapTouch through-glass buttons or the RS-485 serial communication port with free Modbus protocol.

    Why you should buy:
  • The ProVu PD6089 Super Snooper feet & inches Modbus® scanner displays level information on a specially designed feet & inches display, instead of the usual decimal format. It is the ideal display for Modbus level or multivariable transmitters and is capable of scanning up to 16 Modbus process variables. Its unique feet & inches upper LED display can indicate up to 99 feet, 11 and 15/16 inches. The 6-digit lower display can indicate units, tags, or other variables such as volume, temperature, or density. The PD6089 can function as a Modbus master, slave, or snooper. Like all ProVu meters, the PD6089 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy: