Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

Panel Mount

Displaying 27 total products (page 2 of 3):

  • The PD6300 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from a pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeter. It displays that signal on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. Flow rate is typically displayed on the upper line and the cumulative total is displayed on the lower line. The total overflow feature allows up to a 9-digit total and grand total to be displayed. Like all ProVu meters, the PD6300 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6300 includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The Sabre P PD603 process meter combines operational simplicity with high end features to deliver the perfect low-cost 1/8 DIN digital panel meter for display only applications. The PD603’s menu structure is easy to navigate because the only selections are for input, decimal point location, and scaling values; there are no other menu choices to add confusion during the setup process. Despite being a low-cost meter, the PD603 is still packed with many features typically found only on more expensive meters, such as a NEMA 4X front, universal power supply, front panel programming, input current overload protection, UL listing, and CE marking.


    Why you should buy:
    • Low Cost Display Only Option
    • NEMA 4X/IP65 Front
    • Analog Input
  • The PD6100 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts strain gauge & load cell inputs and mV signals up to 300 mV (unipolar) and ± 250 mV (bipolar) for weight indication and force measurement applications. With a max output current of 350 mA at 10 V, it can support up to twelve (12) 350 Ω load cells (minimum load resistance of 28 Ω), making it ideal for multipoint weight measurement applications. The PD6100's dual-line display and powerful dual-scale capability allows the measurement to be displayed in two different units of measure; gallons (volume) could be displayed on the upper line while pounds (weight) is displayed on the lower line, for example. Another use for the PD6100’s dual-line display is to simply show the units of measure on the bottom line. The PD6100 stain gauge meter includes a 24 VDC power supply to drive the sensors and can be equipped with up to four internal relays and two 4-20 mA outputs.

    Why you should buy:
  • The PD7000 is a member of the ProVu series of 1/8 DIN digital panel meters that accepts a direct temperature input from a wide range of temperature measurement devices (type J, K, T, E, R, S, B, N, and C thermocouples and 100 or 1000 Ω platinum, 10 Ω copper, 120 Ω nickel RTDs). It displays the measured temperature in either degrees Fahrenheit or degrees Celsius on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The PD7000 temperature indicator includes automatic cold junction compensation for thermocouples and the ability to average up to ten (10) RTD sensors. Like all ProVu meters, the PD7000 temperature meter includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output and Modbus® RTU serial communications. The PD7000 can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
    • Thermocouple or RTD Input
    • Dual Line Display
    • USB Programming
    • 4 Relays & 4-20 mA Output
  • The ProVu PD6310 is an 1/8 DIN pulse input (NPN, PNP, TTL, switch contact, sine wave, etc.) digital batch controller specifically designed for single and multi-stage batching applications. It provides excellent but simple batch control capabilities with features such as preclose relays and automatic overrun correction for more accurate batches and intuitive front panel buttons for simple operation and menu navigation. The preclose deactivates a specific relay on the batch controller before the batch is finished in order to allow slower fill rates and increased accuracy. Automatic overrun correction keeps the batch size accurate over time and with system wear. With expansion module relays, up to eight-stage batching is possible; each additional stage-batching relay has an individually programmable preclose amount. Like all ProVu meters, the PD6310 batcher includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options.

    Why you should buy:
    • Single or Multi-Stage Batching
    • Pulse Input
    • Displays Batch and Rate
  • The ProVu PD6310-WM is an NTEP® certified, pulse input (NPN, PNP, TTL, switch contact, sine wave, etc.) digital batch controller specifically designed for single and multi-stage batching applications which has been certified as a Weighing and Measuring device. These versatile NTEP certified batch controllers provide excellent but simple batch control capabilities with features such as preclose relays and automatic overrun correction for more accurate batches and intuitive front panel buttons for simple operation and menu navigation. This Weights and Measures approved batch controller is equipped with a mechanically secured, tamper-proof, programming lockout feature. This consists of a cable with a compression seal that is used to prevent access to a programming lockout jumper. Like all ProVu meters, the PD6310 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options.

    Why you should buy:
    • NTEP Weights & Measures Batch Controller
    • Pulse Input
    • Displays Batch and Rate
  • The PD6363 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6363 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6363 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.

    Why you should buy:
  • The Vigilante® II PD150 alarm annunciator provides alarming and monitoring capabilities for all of your level, pressure, flow, and other process switches. These alarm annunciators are available in two models; the PD154 has four (4) inputs and the PD158 has eight (8) inputs. Each model accepts inputs from relays, float switches, digital outputs, and many other discrete (on/off) devices. It can be field programmed for all common ISA alarm sequences including first out indication and provide alarm signaling through front panel LEDs and a built in 85 dB horn. It features a NEMA 4X front, 2 SPDT relays for alarm activated devices, wide operating temperature range, and sunlight viewable alarm indicators. Custom printed message labels can be included with your order at no additional charge.

    PD154
    Why you should buy:
    • 1/8 DIN Panel Mount
    • 4 or 8-Point Monitoring
    • All Common ISA Sequences
  • The ProVu PD6088 Super Snooper Modbus® scanner displays up to 16 Modbus process variables (PVs) on the bus using its RS-485 serial input. The PD6088 can function as a Modbus master, slave, or snooper. As a Modbus master, the PD6088 can poll multiple Modbus devices for up to 16 Modbus process variables. As a slave, a Modbus master can write up to 16 PVs to the scanner for display. In snooper mode, it can sit anywhere on the Modbus network and display up to 16 PVs being polled on the bus. When connecting a scanner in snooper mode, no other Modbus devices on the network need to be reconfigured, making it easy to add additional local or remote displays to a Modbus network. Like all ProVu meters, the PD6088 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. Various math functions may be applied to the analog or Modbus inputs, such as addition, difference, average, and ratio.

    Why you should buy:
  • The MINIMUX® II PD138 is a microprocessor-based, eight-channel analog input scanner/multiplexer and annunciator that provides low-cost automatic switching for multi-point display and alarm systems. It can automatically switch up to eight inputs to another device such as a digital panel meter, controller, or PLC. Signal switching is done via reed relays making the PD138 ideal for switching thermocouples, RTDs, control loops, and AC/DC signals. They feature rugged NEMA 4X/IP65 fronts and a wide operating temperature range. They can be programmed for many common ISA alarm sequences including first out indication and they provide alarm signaling through front panel LEDs and a build in 85 dB horn. Custom printed message labels can be included with your order at no additional charge.

    Why you should buy:
    • Scans Temperature and Analog Inputs
    • Channel Alarms
    • NEMA 4X/IP65 Front