Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

Indoor LCD None Hazardous Area

Displaying 10 total products (page 1 of 1):

  • The Loop Leader PD6600 is an ATEX, IECEx approved, and UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN process meter. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6608) or feet & inches display (PD6607) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered process meter is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6606
    Why you should buy:
  • The ProtEX-Pro PD6800 is one of Precision Digital's most advanced and feature-packed explosion-proof, loop-powered indicators. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. Like all ProtEX products, the PD6800 carries CSA, ATEX, and IECEx approvals for use in hazardous areas. It features a dual-line display that can be easily scaled in the field for any 4-20 mA analog input. The display has a five digit upper display, a seven alpha-numeric character lower display, and is available with a twenty-segment bar graph for level applications. Two features that really make the PD6800 stand out are its wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6800 to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.

    Aluminum or Stainless Steel
  • The PD663 is a loop-powered field meter that is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 connections. The PD663 is easy to install and program and it can be seen in a variety of lighting conditions, even in bright sunlight. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however the display will cease functioning.


  • The PD685 is an easy to use, loop-powered indicator, certified by CSA, ATEX and IECEx as intrinsically safe. The PD685 carries international certifications under both the Class/Division System and Zone System, and is thereby suitable for use in gas and dust hazardous areas worldwide. For Division 2 applications where intrinsically safe interfaces are not needed, the PD685 is able to be installed without barriers! To achieve this ability, the PD685 underwent a special 'nonarcing assessment' under the UL 121201 and CSA C22.2 No. 213 standards, and was determined to be a device incapable of causing an ignition on its own. The PD685 is wellsuited for both indoor and outdoor applications and carries a variety of environmental ratings, including NEMA 4, Type 4X and IP67.

    The PD685 can be seen from considerable distance in bright sunlight or dimly lit areas when the standard backlight feature is activated. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The meter gets all of the power it needs from the 4-20 mA loop and its 1 V (4 V with backlight) drop results in a minimal burden on the loop. The meter features a wide -40 to 75°C operating temperature range and is available with a ½" conduit hole in a location of your choice for easy installation. Calibration is a quick two-step process involving the adjustment of only two sets of coarse and fine, non-interacting potentiometers.


    Why you should buy:
  • The PD6801 is a rugged, full-featured, explosion-proof loop-powered meter specifically designed for level applications in hazardous areas or in the harshest environmental conditions. Instead of the usual decimal display, the meter displays level in feet, inches, and fractions of an inch with a 20-segment tank level indicator. The secondary display can show a custom unit or tag, percent full, or a second scale for the 4-20 mA input used to indicate volume. The backlight feature makes the display visible under any lighting condition and can be powered from either the 4-20 mA loop or from a separate DC power supply.
    Aluminum or Stainless Steel
  • The ProtEX PD6830X is an explosion-proof, RS485 serial input Modbus® RTU scanner capable of scanning up to 16 Modbus variables and displaying them on an easy-to-read, dual-line, LCD display. This Modbus scanner can be programmed as a Modbus RTU master, slave, or snooper. The PD6830X is available in two upper display line configurations: 5-digit decimal display and feet & inches display with bar graph. The lower line is the same for both versions and consists of seven alphanumeric characters. Like all ProtEX products, the PD6830 carries CSA, ATEX, and IECEx approvals for use in hazardous areas. Two features that really make the PD6830X stand out are its wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6830X to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.

  • The PD6820 is a rugged, full-featured, explosionproof loop-powered flow rate/totalizer ideal for demanding applications in hazardous areas or in the harshest environmental conditions. The product is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 conduit connections. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however, the display will cease functioning.
    Aluminum or Stainless Steel
  • The ProtEX-RTP PD6830 is an explosion-proof flow rate/totalizer that can display flow rate and total from a pulse output flowmeter. Its display has a five digit upper line for rate, a seven alpha-numeric character lower line for total, and comes standard with a backlight. Like all ProtEX products, the PD6830 carries CSA, ATEX, and IECEx approvals for use in hazardous areas. It can be powered from an included battery or a 24 VDC external power supply. Some features that really make the PD6830 flow rate/totalizer stand out are its automatic unit conversions from flowmeter k-factor units, ability to log up to 1024 data points, and SafeTouch® through-glass buttons. These buttons allow the PD6830 to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.


    Why you should buy:
  • The ProtEX-FarVu PD6870 is a rugged, explosion-proof, loop-powered meter with 1" display digits ideal for demanding applications in hazardous areas or in the harshest environmental conditions. The product is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 connections. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however, the display will cease functioning.

    Why you should buy:
  • The Loop Leader PD6620 is an ATEX and IECEx approved, UL listed, intrinsically safe and nonincendive, loop-powered, 1/8 DIN flow rate/totalizer designed for demanding process control applications. A dual-line display featuring five digits on the top line and eight digits on the bottom line, preprogrammed engineering units, loop-powered backlight with a unique red backlight option for alarm conditions, and optional bargraph display (PD6628) provide a clear and attractive presentation of the process. All models come equipped with two open collector outputs and are available with two solid state relays and a 4-20 mA analog output. These outputs can be programmed for alarm indication, signal retransmission via pulse or analog signal, pump control, and a number of other useful features. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines; the meter gets all of the power it needs from the 4-20 mA loop. The Loop Leader loop-powered rate/totalizer is built in a shallow-depth case with a IP65 front and features loop-powered backlighting and a wide -40 to 158°F (-40 to 70°C) operating temperature range. It doesn't matter if it's in hazardous areas, indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere.

    PD6626
    Why you should buy: