Meter Selection Utility


Answer nine simple questions about your application to find the exact meter you need.
Don't know the answer to some of the questions? Just fill out what you know!

Single-Line Display

Displaying 11 total products (page 1 of 2):

  • The Trident PD765 digital panel meter is one of the most versatile meters on the market and will satisfy a wide variety of process and temperature applications. Housed in an 1/8 DIN enclosure with a NEMA 4X front, the meter can be field programmed to accept process voltage (0-5 V, 1-5 V, etc.) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. The display height on the standard Trident meter is 0.56" (14.2 mm) and on the Trident X2 the display height is an astounding 1.2" (30.5 mm). The intensity of the display can be adjusted to compensate for various lighting conditions, including direct sunlight. Programming and setup can be performed with the four front panel pushbuttons, free MeterView software, or using the copy function. Options for the PD765 include 2 relays, a 4-20 mA output, 24 V transmitter power supply, and Modbus® serial communications.

    PD765 X2
    Why you should buy:
    • Big Display
    • 1/8 DIN Panel Meter
    • Universal Inputs
    • 2 Relays & 4-20 mA Output
  • The ProtEX-MAX PD8-765 explosion-proof, large-display, process and temperature meter offers all the functionality of the Trident X2 as a CSA, ATEX, and IECEx certified explosion-proof product. It is available in an aluminum or stainless steel enclosure and will operate over a wide temperature range of -55 to 65°C (-67 to 149°F). PD8-765's huge 1.2" (30.5 mm) sunlight readable display that is visible from over 30 feet away. This explosion-proof indicator can be field programmed to accept process voltage (0-5 V, 1-5 V, etc.) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples. The intensity of the display can be adjusted to compensate for various lighting conditions, including direct sunlight. The meter can be programmed and operated without opening the housing by using the built-in CapTouch through-glass buttons or the RS-485 serial communication port with free Modbus protocol. Options for the PD8-765 process and temperature indicator include 2 relays, a 4-20 mA output, and a 24 V transmitter power supply.

    Why you should buy:
  • The PD663 is a loop-powered field meter that is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 connections. The PD663 is easy to install and program and it can be seen in a variety of lighting conditions, even in bright sunlight. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however the display will cease functioning.


  • The Sabre P PD603 process meter combines operational simplicity with high end features to deliver the perfect low-cost 1/8 DIN digital panel meter for display only applications. The PD603’s menu structure is easy to navigate because the only selections are for input, decimal point location, and scaling values; there are no other menu choices to add confusion during the setup process. Despite being a low-cost meter, the PD603 is still packed with many features typically found only on more expensive meters, such as a NEMA 4X front, universal power supply, front panel programming, input current overload protection, UL listing, and CE marking.


    Why you should buy:
    • Low Cost Display Only Option
    • NEMA 4X/IP65 Front
    • Analog Input
  • The PD685 is an easy to use, loop-powered indicator, certified by CSA, ATEX and IECEx as intrinsically safe. The PD685 carries international certifications under both the Class/Division System and Zone System, and is thereby suitable for use in gas and dust hazardous areas worldwide. For Division 2 applications where intrinsically safe interfaces are not needed, the PD685 is able to be installed without barriers! To achieve this ability, the PD685 underwent a special 'nonarcing assessment' under the UL 121201 and CSA C22.2 No. 213 standards, and was determined to be a device incapable of causing an ignition on its own. The PD685 is wellsuited for both indoor and outdoor applications and carries a variety of environmental ratings, including NEMA 4, Type 4X and IP67.

    The PD685 can be seen from considerable distance in bright sunlight or dimly lit areas when the standard backlight feature is activated. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The meter gets all of the power it needs from the 4-20 mA loop and its 1 V (4 V with backlight) drop results in a minimal burden on the loop. The meter features a wide -40 to 75°C operating temperature range and is available with a ½" conduit hole in a location of your choice for easy installation. Calibration is a quick two-step process involving the adjustment of only two sets of coarse and fine, non-interacting potentiometers.


    Why you should buy:
  • The PD650 is a large display, analog input process meter with flow rate/totalizer and batch control capabilities housed in a rugged, die-cast aluminum, NEMA 4X enclosure. It accepts the common process signals such as 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC and displays these signals in engineering units on a 2.3" (58.42 mm) large, high efficiency, 4 1/2 digit LED display. The 115/230 VAC models also provide two isolated 24 V power supplies to drive both the input and output loops. Options include up to 4 relays for alarm or batch control and an isolated 4-20 mA transmitter output.

  • The ProtEX-FarVu PD6870 is a rugged, explosion-proof, loop-powered meter with 1" display digits ideal for demanding applications in hazardous areas or in the harshest environmental conditions. The product is CSA Certified as Explosion-Proof, Dust-Ignition-Proof, and Flame-Proof, and ATEX & IECEx Certified as Explosion-Proof. It is available in either an aluminum or stainless steel enclosure with ¾" or M20 connections. It will operate down to -40°C and is approved for installation in areas where the temperature gets as cold as -55°C, however, the display will cease functioning.

    Why you should buy:
  • The Vantageview PD6770 is a plastic, loop-powered process meter with 1" display digits in a field-mountable enclosure designed for demanding applications. The meter derives all of its power from the 4-20 mA loop with a small 1 V drop, so there is no need to run additional, costly power lines. The PD6770 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. It is programmed using four easy-to-access, front-mounted control dials.




    Why you should buy:
    • NEMA 4X/IP65 Enclosure
    • Loop-Powered
    • Large Digits
    • Backlight Option
  • The PD662 NEMA 4X, CSA Certified loop-powered meter is perfect
    for applications where a simple, inexpensive display is required
    and AC power is not available. The PD662 derives all its power
    from the 4-20 mA loop, including its optional backlight feature. It
    can be easily scaled in the field using four push buttons; with or
    without applying an actual calibration signal. The PD662’s display
    will read up to 2999; we call this 3½+ digits! The PD662 is housed
    in a rugged NEMA 4X enclosure and is provided with one ½" NPT
    pipe conduit hole.


    Why you should buy:
  • The Javelin D is an easy-to-use, 1/8 DIN digital voltmeter that accepts a DC voltage input up to 300 VDC. It features a built-in 4-20 mA isolated transmitter, RS-485 serial communication capability, and a NEMA 4X/IP65 rated front. The four front panel buttons provide quick and simple access to programming and operation functions. There are no jumpers, and no need to ever open the case. After completing setup of one meter, additional meters can be cloned using the time-saving copy function. The optional Form C relays can be used for alarm indication or process control applications. The Modbus® RTU serial communication upgrade enables the Javelin D Digital Voltmeter to operate as a Modbus® slave in RS-485 multi-point data acquisition systems.

    Why you should buy:
    • Up to 300 VDC Input
    • NEMA 4X/IP65 Front