Model: MOD-PD2LH3CB1-RYG

MOD-PD2LH Series PD2 & PD4 Light/Horn Modification

Helios meter ordered separately
SKU: MOD-PD2LH3CB1-RYG
Product Type: Light Stack/Horn with Red, Yellow, Green Lights, Button, and Holes Drilled in Enclosure
Warranty: 1 year
Product Family: MOD-PD2LH
Product category: Accessories & Modifications

Features

  • Light/Horn and Button Mounted and Wired to Meter
  • Single Lights in Red, Green, Yellow, Blue, or White Available
  • Units with One of Five User Selectable Lights Available
  • Three Color Light Stack with Red, Yellow, and Green Lights Available
  • Light/Horn Powered from Meter or External Power Supply
  • Light and Horn Can be Controlled Independently Using Separate Relays
  • Light/Horn Programmable for Variety of Reset Functions, Including:
    • Silence Horn at Any Time
    • Light Stays on Until Alarm Clears
  • Light Can Be Wired to Flash or Stay Steady On
  • IP65 Rated
  • 85 dB Horn
  • Operates from -5 to 40°C (23 to 104°F)
  • Control Station Accessory For Remote Operation of Light/Horn Button

What's Included

Check mark Light/Horn

Light/Horn

Check mark Button

Button and 9 Labels

Check mark Enclosure Drilling

Hole Drilling on Enclosure

X mark Installation

Installation and Wiring

X mark Meter

Meter

 

Meter sold separately.

Overview

Transform a Precision Digital meters and controllers housed in an enclosure into an efficient display, control, and alarm system with the MOD-LH series. It provides a light/horn to boost visibility of alarm conditions, a button that connects to the meter's digital input to control or reset the alarms, and hole drilling on the enclosure for both the light/horn and button to make user installation and wiring quick and easy. Enclosure and meter are sold separately.

The MOD-LH series is compatible with a wide range of Precision Digital NEMA 4 and NEMA 4X enclosures as well as meters and controllers including the ProVu, Trident, Loop Leader, and ConsoliDator+ Series. Overall, the MOD-LH series is a simple solution for Precision Digital meters and controllers that adds audible and visual ways to indicate critical alarms.

Installation of the light/horn accessory voids all of the PD2 and PD4 agency approvals. The NEMA 4X and IP65 ratings are not affected.

MOD-PD2LH Series

PD2 and PD4 Meters Shown with MOD-PD2LHRB1 Red Light/Horn and Button. Meters Sold Separately.

MOD-LH Series Light Color Options

Light/Horn

The light/horn is available in three different light configurations and each comes with a built-in 85 dB horn.

The first light option is a single color light in either red, green, yellow, blue, or white. The second light option is a user selectable light with five color options in either red, green, yellow, blue or white. Simply connect the appropriate wire to display the desired light color. The third option is a light stack with red, yellow, and green lights that can turn on independently (not compatible with PD4).

The light can be wired to flash (not available on MOD-PD2LH5CB1) or stay steady on. Both the light and horn can be controlled independently of each other using separate relays on the meter, and may be reset in a variety of ways based on the connected meter's relay reset capabilities.

MOD-LH Series Button

Button

The button connects to the meter's digital input and it can be used to remotely control the light/horn such as resetting, acknowledging, or silencing an alarm. Nine (9) printed labels are provided to identify the button's action including: RESET, BATCH, ACK, TARE, SILENCE, STOP, START, PAUSE, and START/STOP.

MOD-LH Series Button Labels Provided (9) Printed Labels Provided

Control Capabilities

The light and horn can be controlled independently of each other using separate relays on the Precision Digital meter they are connected to. These relays can be programmed for automatic or manual reset action to satisfy a wide variety of audible and visual alarm applications.

Power Options

Precision Digital meters with an internal transmitter power supply can provide up to 200 mA to power the transmitter and other devices including the light/horn. See Specifications for details on power consumption.

If a meter connected to the light/horn does not have an internal transmitter power supply or more power is required than the meter provides, then consider the PDA1024-01 24 VDC transmitter power supply.

Hole Drilling Locations

All MOD-PD2LH models provide hole drilling on enclosure for light/horn and button. See below for hole locations for both the light/horn and button.

Light/Horn Hole Location

Light/Horn
The light/horn hole is on the top-left of the enclosure.

Button Hole Location

Button
The button is centered on the cover of the enclosure below the display.

Connections

MOD-PD2LH Connections

MOD-PD2LH Models

Connections shown for a red light model. For other MOD-PD2LH models, the red wire is the color of the light. Connect the red and black wires for a Steady On light and red and gray wires for Flashing light.

MOD-PD2LH5CB1 Connections

MOD-PD2LH5CB1

Connect the LED color to the plus supply and the black wire to the minus supply to turn the LED on. Be aware of limitations for applications requiring different color lights for different alarm conditions.

MOD-PD2LH3LCB1-RYG Connections

MOD-PD2LH3LCB1-RYG

Connect the LED color to the plus supply for a Steady On light and LED color and gray wires to the plus supply for Flashing light. The black wire should be connected to the minus supply.

Applications

There are a wide variety of ways these light/horn devices can be controlled by Precision Digital meter's relays to satisfy visual and audible alarm applications. Feel free to contact tech support to discuss your particular application. The following examples illustrate some typical applications.

MOD-PD2LH Models

MOD-PD2LH Wiring
PD2 meter with internal transmitter power supply connections shown

The MOD-PD2LH models are the simplest devices in the series and are made up of a single-color light and horn. A typical way to use the MOD-PD2LH is to program the meter so that the horn can be silenced at any time via a button connected to the meter's digital input or via the F3 front panel button, and the light to reset automatically when the alarm clears:


RelayConnected toDefault Reset
1Flashing Light(1)Auto reset
2HornSilence with Button at any time
3User DeviceAs user desires
4User DeviceAs user desires
1 Light can be wired to flash or stay steady on.

MOD-PD2LH5CB1

MOD-PD2LH5CB1 Wiring
PD2 meter with internal transmitter power supply connections shown

The MOD-PD2LH5CB1 shows one color at a time and the light color (red, green, yellow, blue or white) is determined by which wires are connected to power through the meter’s relays. A typical application for the MOD-PD2LH5CB1 might involve lighting up the red light to indicate high and low alarms and the green light to indicate everything is OK using a Precision Digital meter's four internal relays:


RelayPurposeLight/HornAction
1Low alarmRed lightAuto
2All OKGreen lightAuto
2High alarmRed lightAuto
3Low alarmHornLatch
4High alarmHornLatch

MOD-PD2LH3LCB1-RYG

MOD-PD2LH3LCB1-RYG Wiring
PD2 meter with internal transmitter power supply connections shown

The MOD-PD2LH3LCB1-RYG can light up red, yellow or green lights as determined by which wires are connected to power through the meter's relays. A typical application for the MOD-PD2LH3LCB1-RYG (and the default factory setting) might involve lighting up the green light to indicate everything is OK, the yellow light to indicate a High warning, and the red light to indicate a High alarm. The Horn will also sound at both the Warning and High alarms and can be manually reset at any time via a button connected to the meter's digital input or via the F3 front panel button:


RelayPurposeLight/HornAction
1All OKGreen lightAuto
2WarningYellow lightAuto
2High alarmRed lightAuto
3WarningHornLatch
4High alarmHornLatch

Watch the Light/Horn Video



You may be interested in

Light/Horn Series
PDA-LH Series

Light/Horns

What's included:

  • Light/Horn
  • Ideal for custom user installations
Light/Horn Enclosure Modification
MOD-LH Series

Light/Horn Enclosure Modification

What's included:

  • Light/Horn
  • Button and 9 Labels
  • Hole Drilling on Enclosure

Meter and enclosure sold separately. User installation and wiring required.

Note: These specifications apply to the entire product series and may contain information that is not relevant to this particular model number.

General

InstallationHoles drilled in enclosure for light/horn and button. User installation and wiring required.
EnvironmentalOperating Temperature Range:
-5 to 40°C (23 to 104°F)
ApprovalsInstallation of the light/horn accessory voids all of the PD2/PD4 agency approvals. The NEMA 4X and IP65 ratings are not affected.
Warranty1 year parts and labor. See Warranty Information and Terms & Conditions for complete details.

Light/Horn

Light/Horn IndependenceLight and horn can be controlled independently via separate relays.
RatingIP65
ConnectionM22
Hole Size0.875" (22 mm)
Cable Length3.28 feet (1 meter)
Light ColorsMOD-PD2LHRB1: Red
MOD-PD2LHGB1: Green
MOD-PD2LHYB1: Yellow
MOD-PD2LHBB1: Blue
MOD-PD2LHWB1: White
MOD-PD2LH5CB1: User selectable: red, green, yellow, blue, white.
MOD-PD2LH3LCB1-RYG: Light stack with red, yellow, green lights (consult factory for other colors).
Light ActionCan be wired to flash or stay steady on (Flashing not available on PDA-LH5C)
Sound85 dB
Overall Dimensions2.2" x 4.8" X 2.2" (55 x 122 x 55 mm)
(W x H x D)
Weight8 oz (227 g)

Button

RatingIP67, NEMA 4X
ConnectionM16
Hole Size0.630" (16 mm)
ActionWire to the meter's digital input to reset, acknowledge, or silence an alarm.
LabelsNine (9) labels provided: RESET, BATCH, ACK, TARE, SILENCE, STOP, START, PAUSE, START/STOP

Power

Power Required24 VDC
Transmitter Power SupplyPrecision Digital meters with an internal transmitter power supply can supply up to 200 mA to power the transmitter and other devices including the PDA-LH series light/horn. The following tables illustrate how much power is required to power various light colors and the horn.
MOD-PD2LH and MOD-PD2LH5CB1 Models
ColorPower Required
Red17 mA
Green15 mA
Yellow23 mA
Blue15 mA
White42 mA
Horn20 mA
Example:
17 mA (Red Light) + 20 mA (Horn) = 37 mA total current needed from the 200 mA supply. Available current = 163 mA
MOD-PD2LH3LCB1-RYG Model
ColorPower Required
Red34 mA
Green29 mA
Yellow33 mA
Horn38 mA
Example:
33 mA (Yellow Light) + 38 mA (Horn) = 71 mA total current needed from the 200 mA supply. Available current = 139 mA
External Power SupplyIf a meter connected to the light/horn does not have an internal transmitter power supply or more power is required than the meter provides, then consider the PDA1024-01 24 VDC transmitter power supply.

Meter Compatibility

SeriesModelsMOD-PD2LHMOD-PD2LH5CB1MOD-PD2LH3LCB1-RYGLight/Horn Powered by MeterLight/Horn Requires External PowerReset Capabilities
HeliosPD2-6000, PD2-6001, PD2-6060, PD2-6080, PD2-6081, PD2-6200, PD2-6210, PD2-6300, PD2-6310 
PD2-6100, PD2-6262, PD2-6363, PD2-6400, PD2-7000 
Loop Leader+PD4-6603, PD4-6604, PD4-6624  

Note: This tab applies to the entire product series and may contain information that is not relevant to this particular model number.

Dimensions

Light/Horn

Light/Horn Dimensions

Button

Button Dimensions

Connections

PD2 Helios Series Connections (Internal Power)

Wiring Connections for MOD-PD2LH Models Using Helios Meter Internal Power Supply MOD-PD2LH Models Using Internal Power Supply
Wiring Connections for MOD-PD2LH5C Models Using Helios Meter Internal Power Supply MOD-PD2LH5C Models Using Internal Power Supply
Wiring Connections for MOD-PD2LH3LC-RYG Models Using Helios Meter Internal Power Supply MOD-PD2LH3LC-RYG Models Using Internal Power Supply

PD2 Helios Series Connections (External Power)

Wiring Connections for MOD-PD2LH Models Using PDA1024-01 External Power Supply MOD-PD2LH Models Using External Power Supply (PDA1024-01)
Wiring Connections for MOD-PD2LH5C Models Using PDA1024-01 External Power Supply MOD-PD2LH5C Models Using External Power Supply (PDA1024-01)
Wiring Connections for MOD-PD2LH3LC-RYG Models Using PDA1024-01 External Power Supply MOD-PD2LH3LC-RYG Models Using External Power Supply (PDA1024-01)

PD4 Loop Leader+ Series Connections

Wiring Connections for MOD-PD2LH Models Using PDA1024-01 External Power Supply MOD-PD2LH Models Using External Power Supply (PDA1024-01)
Wiring Connections for MOD-PD2LH5C Models Using PDA1024-01 External Power Supply MOD-PD2LH5C Models Using External Power Supply (PDA1024-01)

Add to Cart

SKU: MOD-PD2LH3CB1-RYG
Stock: 0
Lead Time: 5 business days
Price:
Price$444.00