EXPLOSION-PROOF, INTRINISICALLY SAFE, & NONINCENDIVE METERS, DISPLAYS & CONTROLLERS
Precision Digital products can be located in a wide variety of hazardous areas. We provide products that are intrinsically safe, non-incendive, explosion-proof or can be housed in explosion-proof enclosures. Loop-Powered Meters
| Panel Mount |
Model |
# of Digits |
Digit Height |
Voltage Drop |
Input 4-20 mA |
Display Features |
Approvals |
Temperature Range |
 |
PD688 |
5 |
0.6" |
2.7 V (5.7 V with backlight) |
Linear, Square root, & Programmable exponent |
Backlight Engineering units Bargraph Engineering notation Trend arrows |
FM & CSA |
-40 to 65°C |
 |
F090 |
5½ |
1.0" |
2.6 V |
Linear & Square root |
Backlight Engineering units Piegraph Engineering notation Trend arrows |
ATEX & CSA |
-40 to 70°C |
| NEMA 4X |
Model |
# of Digits |
Digit Height |
Voltage Drop |
Input 4-20 mA |
Display Features |
Approvals |
Temperature Range |
 |
PD686 |
3½ |
1.0" |
1.0 V |
Linear |
|
FM & CSA |
-40 to 85°C |
 |
PD675 |
4½ |
0.7" |
5.2 V |
Linear |
|
FM & CSA |
-20 to 65°C |
|
F090 |
5½ |
1.0" |
2.6 V |
Linear & Square root |
Backlight Engineering units Piegraph Engineering notation Trend arrows |
ATEX & CSA |
-40 to 70°C |
| Explosion-Proof |
Model |
# of Digits |
Digit Height |
Voltage Drop |
Input 4-20 mA |
Display Features |
Approvals |
Temperature Range |
 |
PD661 |
3½ |
0.5" |
1.5 V 3.5 V w/ backlight |
Linear |
Backlight option |
FM & CSA |
-40 to 80°C |
 |
PD687 |
3½ |
1.0" |
1.0 V |
Linear |
|
FM & CSA |
-40 to 80°C |
 |
PD677 |
4½ |
0.7" |
5.2 V |
Linear |
|
FM & CSA |
-20 to 65°C |
 |
F090 with PDA2448 |
5½ |
1.0" |
2.6 V |
Linear & Square root |
Backlight Engineering units Piegraph Engineering notation Trend arrows |
ATEX & CSA |
-40 to 70°C |
Meters in Explosion-Proof Enclosures
Precision Digital can supply explosion-proof enclosures that can house one or two Precision Digital meters or one Fluidwell instrument.
 Model PDA2448
|
|
Explosion-Proof Control Stations |

|
- One, Two, Three Buttons
- UL and C-UL classified
- Class I Groups C & D
- Class II Groups E, F, G
|
PD656 Explosion-Proof Meter |
- 4-20 mA, 1-5 V, 0-10 V inputs
- 0.8" (20.3 mm) red LED display
- Transmitter power supply
- 4 relays & 4-20 mA output options
|
|
Hazardous Area Flow Rate/Totalizers
| Model |
PD689 |
PD698 |
PD656 |
| |
 |
|
|
| Description |
Rate/Totalizer |
Rate/Totalizer |
Rate/Totalizer |
| Case |
Panel mount |
Explosion-proof |
Explosion-proof |
| Panel Cutout |
1/8 DIN |
N/A |
N/A |
| Material |
Plastic |
Aluminum |
Aluminum |
| Display Type |
LCD |
LCD |
LED |
| Display Format |
Alternating |
Alternating |
Alternating |
# of Digits: rate
|
5 |
4½ with extra zero |
4½ with extra zero |
| # of Digits: total |
5
|
6 |
6 |
| # of Digits: Acc total |
N/A |
N/A |
N/A |
| Digit Height |
0.5" |
0.5" |
0.8" |
| Eng Units Display |
Yes |
No |
No |
| Backlight |
Standard |
Yes |
N/A |
| Bargraph |
Standard |
N/A |
N/A |
| Input(s) |
4-20 mA |
4-20 mA |
4-20 mA 0-10 V |
| Linearization |
Square root & programmable root |
Square root |
2 to 11 points |
| Voltage Drop |
2.0 V w/o backlight 5.7 V with backlight |
5.6 VDC w/o Backlight 7.0 VDC w/ Backlight |
N/A |
| Alarms |
high or low rate alarm |
N/A |
4 |
| Relays |
N/A |
N/A |
2 or 4 Form C |
| Analog Output |
N/A |
N/A |
Yes |
| Pulse Output |
250 pulses/sec max |
Isolated open collector |
None |
| Power |
Loop-powered |
Loop-powered |
AC or DC |
| Temperature Range |
-40 to 65°C |
0 to 65°C |
-20 to 65°C |
| >Approvals |
FM & CSA |
FM & CSA |
Enclosure only |
Hazardous Area Fluidwell Flow Rate/Totalizers |

|
 F011 with backlight on |
 F012, F014, F110, F016, F112 |
 F111 with backlight off |
 F013 & F113 in alarm condition |
| Hazardous Area Flow Rate/Totalizers |
Linearization |
High/Low Alarms |
| |
F010 |
F011 |
F012 |
F014 |
F110 |
F111 |
F115 |
F016 |
F112 |
F118 |
F013 |
F113 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
|
|
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
|
|
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
|
|
|
|
|
|
|
| Actual flo rate |
|
|
|
|
|
|
|
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
|
|
|
|
|
|
|
| Accumulated total (non-resettable) |
|
|
|
|
|
|
|
|
|
|
|
|
| Multi-point linearization |
|
|
|
|
|
|
|
|
|
|
|
|
| Analog output (flow rate) |
|
|
|
|
|
|
|
|
|
|
|
|
| Pulse output assigned to total |
|
|
|
|
|
|
|
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
|
|
|
|
|
|
|
| Flow direction detection |
|
|
|
|
|
|
|
|
|
|
|
|
| Dual input |
|
|
|
|
|
|
|
|
|
|
|
|
| External reset total |
|
|
|
|
|
|
|
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
|
|
|
|
|
|
|
| Intrinsically safe or exp-proof |
CSA & ATEX |
CSA & ATEX |
CSA & ATEX |
CSA & ATEX |
ATEX |
ATEX |
ATEX |
CSA & ATEX |
ATEX |
ATEX |
CSA & ATEX |
ATEX |
| Backlight |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Explosion-Proof Enclosures For Fluidwell Flow Rate/Totalizers
Click here for other Flow Rate/Total applications
Click Here to launch the fluidwell Configurator
Hazardous Area Flow Computers
|

|
 F126-EL with backlight on |
 F126-EG with backlight off |
 F114 with ratio in alarm condition |
 F116 & F127-EL with sum/differential |
| Hazardous Area Flow Computers |
Ratio |
Differential/sum |
| |
F126-EL |
F126-EG |
F114 |
F116 |
F127-EL |
| |
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
| Actual flow rate |
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
| Accumulated total(non-resettable) |
|
|
|
|
|
| Actual temperature |
|
|
|
|
|
| Actual pressure |
|
|
|
|
|
| Analog output (flow rate) |
|
|
|
|
|
| Pulse output assigned to total |
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
| Temperature compensation |
|
|
|
|
|
| Pressure compensation |
|
|
|
|
|
| Dual input |
|
|
|
|
|
| Fuel compensation calculation |
|
|
|
|
|
| Sum calculation (add on) |
|
|
|
|
|
| Ratio calculation |
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
| Intrinsically safe or exp-proof |
ATEX |
ATEX |
ATEX |
ATEX |
ATEX |
| Backlight |
|
|
|
|
|
|
Explosion-proof enclosures For Fluidwell Flow Computers
Click here for other Flow applications
Click Here to launch the
Fluidwell Configurator
Hazardous
Area Batch Controllers
|

|
 F030, F130, & F136 with batch paused & backlight off |
 F131 & F133 with backlight on |
| Hazardous
Area Batch Controllers/Dispensers |
| |
F030 |
F130 |
F131 |
F133 |
F136 |
| |
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
| 0-20 mA, 4-20
mA input |
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
| Actual flow
rate |
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
| Accumulated
Total (non-resettable) |
|
|
|
|
|
| Batch controller |
|
|
|
|
|
| Preset and
actual value |
|
|
|
|
|
| Analog output assigned to rate |
|
|
|
|
|
| Pulse output
assigned to batch process |
|
|
|
|
|
| Pulse output assigned to total |
|
|
|
|
|
| 1 stage control
output |
|
|
|
|
|
| 2 stage control output |
|
|
|
|
|
| Ticket printing |
|
|
|
|
|
| Overrun correction |
|
|
|
|
|
| External start/stop |
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
| Intrinsically safe or exp-proof |
CSA & ATEX |
ATEX |
ATEX |
ATEX |
ATEX |
| Backlight |
|
|
|
|
|
|
Explosion-Proof Enclosures For Fluidwell Batch Controllers
Click here for other Batch Control applications
Click Here to launch the Fluidwell Configurator
Explosion-Proof Enclosures For Fluidwell Level Indicators
Click Here to launch the Fluidwell Configurator
Explosion-proof Level measurement
Precision Digital's model PD656 Explosion-proof meter is powering the level transmitter and displaying its output on an easy to ready 0.8" high LED display. The PD656 can be equipped with up to four relays that feature 0-100% deadband and pump alternation capability.
Click here for other Level Display and Control applications
Hazardous
Area Pressure Indicators |
|
 F053 with backlight off |
 F151 with backlight on |
| Hazardous Area Pressure Indicators |
High/low alarms |
| |
F050 |
F151 |
F053 |
F153 |
| |
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
| 0-10 V input |
|
|
|
|
| Actual pressure & engineering |
|
|
|
|
| Analog Output |
|
|
|
|
| High & low alarms |
|
|
|
|
| Dual inputs |
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
| Intrinsically safe or exp-proof |
CSA & ATEX |
ATEX |
CSA & ATEX |
ATEX |
| Backlight |
|
|
|
|
|
Explosion-Proof Enclosures For Fluidwell Pressure Indicators
Click Here to launch the Fluidwell Configurator
| Hazardous Area Digital Pressure Gauges |
| |
|
|
| Model |
PD213, PD214, PD224 |
PD233, PD243, PD253 |
| Type |
Industrial |
Precision Test |
| Accuracy |
0.25% FS |
0.05%, 0.10%, or 0.25% FS |
| Case Size |
3", 4½" |
3" |
| Case Material |
(3") 300 Series stainless steel (4½") Fiberglass reinforced thermoplastic or black painted aluminum |
300 Series stainless steel;Electropolished |
| Wetted Materials |
17-4 PH stainless steel sensor; 316 stainless steel socket |
316 stainless steel |
| Socket Size |
¼"NPT, (½" NPT: 4½" case only) |
¼"NPT |
| Connection |
Lower (6 oclock) |
| Ranges |
Vac. to 20,000 psi & compound (see other engineering units below) |
Vac. to 7,000 psi & compound (see other engineering units below) |
| Power Options |
(3") Two AA alkaline batteries (4½") Two C alkaline batteries Loop-powered or 12-36 VDC |
Three AAA alkaline batteries |
| Battery Life |
(3") >1,000 hrs, (4½") >3,600 hrs |
>1,000 hrs |
| On/Off |
Manual on/off Auto off: never, 5, 10, 20 min |
| Display |
5 digit LCD |
5 digit LCD |
| Digit Height |
(3") 0.60", (4½") |
0.66" |
| Backlight |
Option Auto off: 10 sec, 30 sec, 1 min, 5 min |
Standard Auto off: 10 sec, 30 sec, 1 min, 5 min |
| Engineering Units |
psi, mmHg, inHg, inH2O (temperature options: 4°C, 20°C, 60°F), mBar, ftH2O, MPa, kPa, kg/cm2, Bar |
psi, inHg, inH2O, ftSW, Bar, mBar, kPa, MPa, mmHg, cmH2O, mmH2O, kg/cm2 |
Field Calibration |
Zero & span Zero, mid-point & span Password protected |
Zero & span Password protected |
Programming Method |
Front panel |
| Max/MinDisplay |
Max & Min |
| Zero/Clear |
Zeros display or clears max/min |
| Relays |
2 Form C (-2 power only) |
N/A |
| Relay Operation |
High or low alarm |
N/A |
| 4-20 mA Output |
N/A |
| Operating Temperature |
-10 to 60°C |
-18 to 65°C |
| Approvals |
CE, EN 50082-1 (1997) FM & CSA (option) |
CE, EN 50082-1 (1997) FM & CSA |
|
More Information |
Click Here |
Click Here |
Loop-Powered Meters For Pressure Transmitters and Transducers
Click here for other Pressure Display and Control applications
Hazardous Area Temperature Indicators |
|
 F143 with high/low alarm in in alarm condition |
 F040 Dual temperature indicator with backlight on |
| Hazardous Area Temperature Indicators |
High/low alarms |
| |
F040 |
F043 |
F143 |
| |
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
| 0-10 V input |
|
|
|
| 100 ohm RTD (Pt100) |
|
|
|
| Actual temperature & engineering units |
|
|
|
| Analog Output |
|
|
 |
| High & low alarms |
|
|
|
| Dual input |
|
|
|
| RS-232, RS-485, TTL |
|
|
 |
| Intrinsically safe or exp-proof |
CSA & ATEX |
CSA & ATEX |
ATEX |
| Backlight |
 |
 |
 |
|
Explosion-Proof Enclosures For Fluidwell Temperature Indicators
Click Here to launch the Fluidwell Configurator
Explosion-Proof Temperature Indicator
Trident temperature meters mounted inside an explosion-proof enclosure
Click here for other Temperature applications |
|