Precision Digital offers serial adapters and converters and expansion modules to add versatility to its line of ProVu digital panel meters.
Serial adapters are available for RS-232 and RS-422/485 applications and can connect to the ProVu via the standard Precision Digital serial protocol.
One very important feature of these serial adapters is that they are external devices, so one adapter can be used to program as many ProVus from a computer as desired.
Serial converters are available to convert RS-232 and USB to RS-422/485. These converters are available in both isolated and non-isolated versions and will work with any serial device, such as Nova controllers, Fluidwell flow computers, ConsoliDators or any other device with a serial port.
A free software utility is available to program the ProVu’s 32-point linearization feature.
Expansion modules are available to add 4 relays and digital I/O capabilities to the ProVu.
For general information on serial communications, click here.
For complete information on Precision Digital’s serial adapters and converters, see Serial Communication Converters & Adapters: Instruction Manual listed at end of this page.
There are two expansion modules available: four relays and digital I/O
|
PDA1002 DIN-RAIL MOUNTING KIT FOR EXPANSION MODULES |

|
Rail: 6" long Mounting Clips: 4 plastic mounting clips with adhesive strips Total Capacity: 2 expansion modules |
PDA1004 ProVu 4-RELAY EXPANSION MODULE |

|
Relays: Four Form A (SPST); Rated 3 A @ 30 VDC and125/250 VAC for resistive loads 1/14 HP @ 125/250 VAC for inductive loads Cable: Standard CAT5e cable; provided with module. Note: to ensure optimum performance use only supplied cables Connectors: RJ45; identical and interchangeable. Removable screw terminal blocks that accept 12 to 22 AWG wire Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm) Enclosure: ABS-94HB material, UL94HB (Flame-Class Rating) Overall Dimensions: 2.286” x .924” x 3.624” (W x H x D), 58.06 mm x 23.47 mm x 92.05 mm (W x H x D)
Power: ProVu meter M-LINK connection Weight: 2.4 oz (68 g)
DIN-Rail Mounting Kit for up to Two Expansion Modules Available, P/N PDA1002
|
PDA1044 ProVu DIGITAL I/O EXPANSION MODULE |
 |
System: Up to 2 modules for a total of 8 inputs & 8 outputs. Note: The jumper located between the RJ45 connectors must be removed on the second module in order for the system to recognize it as module #
Digital Input Logic High: 3 to 5 VDC
Digital Input Logic Low: 0 to 1.25 VDC
Digital Output Logic High: 4.75 to 5 VDC
Digital Output Logic Low: 0 to 0.4 VDC
Source Current: 10 mA maximum output current
Sink Current: 1.5 mA minimum input current
+5V terminal: To be used as pull-up for digital inputs only. Connect normally open pushbuttons across +5 V & DI1-4
Cable: Standard CAT5e cable; provided with module. Note: to ensure optimum performance use only supplied cables
Connectors: RJ45; identical and interchangeable. Removable screw terminal blocks that accept 12 to 22 AWG wire
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Enclosure: ABS-94HB material, UL94HB (Flame-Class Rating)
Overall Dimensions: 2.286” x .924” x 3.624” (W x H x D), 58.06 mm x 23.47 mm x 92.05 mm (W x H x D)
Power: ProVu meter M-LINK connection
Weight: 2.2 oz (62 g)
|
PDA1200 ProVu METER COPY CABLE
|

|
Cable: 3' (0.9 m) standard modular cable provided with PDA1232 and PDA1485. Also sold separately |
PDA1232 ProVu RS-232 ADAPTER
|

|
Compatibility: EIA-232
Connectors: PC compatible 9-pin D subminiature connector (DB9) and RJ11 (adapter to meter)
Cable: 6’ (1.8 m) standard Cat5e cable provided with adapter
Distance: Adapter to ProVu meter: 6’ (1.8 m) max; Adapter to computer: 50’ (15 m) max; serial interface cable not provided
Power: Powered by ProVu meter M-Link connection
Status Indiciation: Separate LEDs for Power (P), Transmit (TX), and Receive (RX)
|
PDA1485 RS-422/485 SERIAL ADAPTER |

|
Compatibility: EIA-422 and EIA-485
Connectors: Removable screw terminal connector and RJ11 (adapter to meter)
Cable: 6’ (1.8 m) standard Cat5e cable provided with adapter
Distance: Adapter to to ProVu meter: 6’ (1.8 m) max; Adapter to computer: 3,937’ (1,200 m) max
Power: Powered by ProVu meter M-Link connection
Status Indiciation: Separate LEDs for Power (P), Transmit (TX), and Receive (RX)
|
PDA7485 RS-232 to RS-485 CONVERTER |

|
Compatibility: EIA-232, EIA-422, and EIA-485 Connectors: Screw terminal connector and DB9 Distance: RS-232 connection: 50' (15 m) max; RS-422/485 connection: 3,937' (1,200 m) max Number of Units: Up to 31 RS-485 compatible devices
Power: 9-12 VDC; 115 VAC/12 VDC adapter included
Isolation: PDA7485-I: 1500 VAC between data lines; 700 VDC input/output-to-power
PDA7485-N: 1500 VAC between data lines only |
PDA8232-N USB TO RS-232 CONVERTER
|

|
Compatibility: USB 1.1, Usb 2.0, Eia-232
Connectors: PC compatible 9-pin d subminiature connector (DB9) and USB type A
Drivers: Windows® 98/2000/Me/XP
Distance: USB connection: 10’ (3 m) max; rs-232 connection: 50’ (15m) max
Power: USB port
|
PDA8485 USB TO RS-485 CONVERTER
|

|
Compatibility: USB 1.1, USB 2.0, EIA-422, and EIA-485
Connectors: Screw terminal connector and USB Type B
Drivers: Windows 98/2000/ME/XP, Linux 2.4 & greater
Distance: USB connection: 10' (3 m) max; RS-422/485 connection: 3,937' (1,200 m) max
Number of Units: Up to 31 RS-485 compatible devices Power: USB port
Isolation: PDA8485-I: 1500 VAC between data lines; 700 VDC input/output-to-power.
PDA8485-N: 1500 VAC between data lines only |