What's New at Precision Digital News from Precision Digital Rate/Totalizers, Fluidwell, NOVA Rate/Totalizers, Fluidwell, NOVA Precision Digital Pricelists Precision Digital Services Precision Digital Support Services Instrumentation Design & Sales JobsContact Precision Digital CorporationView Precision Digital Videos
PDA7503 MeterView Software
   
   


Programming Data Acquisition MeterView Video Specifications

Download Information Documentation









Features
  • Program or Read Meter Settings
  • Save Meter Profiles for Cloning
  • Configure Meter Input
  • Configure Relay and Alarm Settings
  • Edit Advanced and Security Settings
  • Log Up To 100 Meters
  • Data Saved in HTML Data Files
  • Free Download

Try the Trident VirtualMeter
MeterView® software allows remote programming and data acquisition of the Trident series. The remote programming allows for all available meter settings to be programmed from a personal computer through an easy user-friendly interface. The data acquisition allows the user to gather readings from up to 100 meters at user-selected intervals and generate charts using common tools like Microsoft® Excel.

PROGRAMING

One of the great things about the Trident meter is that serial adapters are external to the Trident meter. That means you buy just one adapter and use it with the free MeterView software to program as many Tridents as you want.


Configure Input
  • Input type
  • Decimal point
  • Temp units
  • Sensor type
Set Relays/Alarms
  • Select mode
  • Set/reset points
  • Fail-safe operation
  • On & off delays
Meter Scaling
  • Scale input
  • No cryptic codes
  • Simple to use
Advanced Settings
  • Password
  • Filter & bypass
  • Transmit delay
  • Function type
  • Cutoff value

Calibration Reporting

Printed by MeterView 3.00 - Build 2060 Printed on 3/18/2003 3:45:28 PM
PD765 Configuration - Meter #00
Input Configuration
Input selected: 4 to 20 mA
Decimal point: ddd.d
Temperature unit: Degrees F
Temperature sensor: Type J
 
Current Scaling (4-20 mA)
Input 1: 4.00
Display 1: 0.0
Input 2: 20.00
Display 2: 200.0
 
Voltage Scaling (0-10 V)
Input 1: 0.00
Display 1: 0.0
Input 2: 10.00
Display 2: 50.0
 
Relay/Alarm 1 Settings
Action: Automatic Reset
Fail-safe: Off
Set point: 40.0
On Delay: 0
Reset point: 10.0
Off Delay: 0
 
Relay/Alarm 2 Settings
Action: Automatic Reset
Fail-safe: Off
Set point: 40.0
On Delay: 0
Reset point: 10.0
Off Delay: 0
 
Display Response Variables
Adjustment: 0.0
Filter: 10
Bypass: 0.2
Transmit delay: 0
 
Miscellaneous
Password: _ _ _ _
Meter address: 00
Serial number: 200111201423430
 
Factory Calibration Constants
Current gain: 0.0340963
Current offset: -0.1501465
Voltage gain: 0.0175513
Voltage offset: -1.0410160
Test gain: 0.0169000
Test offset: -0.0507000
TC Type J gain: 1.0454590
TC Type J offset: 6947.075
TC Type J CJ ref.: 34415.38
TC Type K gain: 1.0459060
TC Type K offset: 6910.510
TC Type K CJ ref.: 34463.38
TC Type T gain: 1.0452330
TC Type T offset: 6920.954
TC Type T CJ ref.: 34447.75
TC Type E gain: 1.0452550
TC Type E offset: 6951.981
TC Type E CJ ref.: 34443.00
RTD 100 Ohm PT (385) gain: 1.0422950
RTD 100 Ohm PT (385) offset: 6221.340
RTD 100 Ohm PT (392) gain: 1.0422950
RTD 100 Ohm PT (392) offset: 6221.340
 



DATA ACQUISITION

Digital Panel Meters make a great front end to a PC-based data acquisition system. They are easy to set up, can be used for a wide range of inputs, will power the transmitter, and best of all provide a local display of the process. Precision Digital has the perfect package with its Trident Digital Panel Meters, a wide selection of serial adapters and converters and MeterView software. Data is displayed on the PC and written to a file that could then be imported into a spreadsheet or other application


Sample File Generated by MeterView®

Digital Panel meters, MeterView Logfile

Monitor One Meter (PDA7503-1)



Monitor One to Ten Meters (PDA7503-2)



Monitor One to One Hundred Meters (PDA7503-3)


METERVIEW VIDEO


View MeterView Video
Dialup | Broadband

SPECIFICATIONS

System Requirements: Windows® 95/98/ME/NT4/2000/XP
Communications: RS-232 adapter or RS-422/485 adapters with an RS-232 to RS-485 or USB to RS-485 converter may be used for communicating with the meters.
Number of Meters: Up to 100 meters simultaneously with addressing capability; minimum scan time for 100 meters: 60 sec
Meter Address: 00 to 99
Baud Rate: 300 bps to 19,200 bps; selection must match the baud rate selected in the meters.
Screen Update Rate: Dependent on system and meter settings. Rates of up to 10 meters/second are attainable at 19,200 bps.
Configuration: Configure meter settings one meter at a time.
Configuration Report: Save configuration to PDC file format or export to HTML for printing, cloning, or restoring meter.
Logging Interval: 2 seconds to 60 hours or manual
Manual Logging: Data saved to file when Log button is pressed.
Data Logging Report: Log data to HTML file format. All enabled meters are logged to a single file.
Alarm Notification: Pop-up message indicates new alarm condition. Alarm alert notification may be disabled.
Event Log: Important events are logged with date and time stamp.
Relay/Alarm Status: Indicate relay/alarm status with customized color and message label. Relay status indication may be disabled.
Units & Tag Number: Show engineering units and tag number information; these settings are not saved to the meter.
Relay Acknowledge: Relays may be acknowledged by clicking on corresponding Relay Status button. Meters must be set up for manual reset and Relay Mode must be enabled in MeterView.

Disclaimer
The Information contained in this document is subject to change without notice. Precision Digital Corporation makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose.

ORDERING INFORMATION

Product Information
Model# of MetersDescriptionDownload
PDA7503-11MeterView SoftwareClick Here
PDA7503-21-10MeterView SoftwareClick Here
PDA7503-31-100MeterView SoftwareClick Here
 
Accessories
Model DescriptionPrice
PDA7232Trident RS-232 Serial Adapter, PDA7420 Included$79  
PDA7422Trident RS-422/485 Serial Adapter, PDA7420 Included$79  
PDA7485-IRS-232 to RS422/485 Isolated Converter $169
PDA7485-NRS-232 to RS422/485 Non-Isolated Converter$139
PDA7488Trident RS-232 & RS-485 Isolated Multi-Input Adapter Board$209
PDA8232-NUSB to RS-232 Converter $49  
PDA8485-IUSB to RS-422/485 Isolated Converter$189
PDA8485-NUSB to RS-422/485 Non-Isolated Converter$159
PDA9485-01Ethernet Serial Server$389

Data Acquisition System for Ten Analog Inputs

Digital Panel Meters make a great front end to a PC-based data acquisition system. They are easy to set up, can be used for a wide range of inputs, will power the transmitter, and best of all provide a local display of the process. The following system will provide a local display of 10 analog inputs and remote display and data acquisition using a PC:

QtyModelDescriptionPrice per unit
10PD765-6R2-10Trident with 2 Relays & 24 VDC Transmitter Supply$309
10PDA7422Trident RS-422/485 Serial Adapter$79  
1PDA8485-IUSB to RS-422/485 Isolated Converter$189
1PDA7503-2MeterView® Software for 1-10 MetersFree 

DOCUMENTATION
PDA7503: Instruction Manual
PDA7503: Data Sheet
Serial Communication Adapters
Save Money Using Serial Adapters
PDC Serial Communication Protocol
PDC Modbus Register Tables
Broadband MeterView Video
Dial-up Meterview Video
MeterView Zip File

See How You can Use Precision Digital Products for
View Flow Level, Pressure and Temperature Applications
 What's New | News | Products | Pricelist | Services | Support | Jobs | Contact Us | Site Map
Precision Digital: Distributors and Manufacturers of Digital Panel Meters and Indicators
View Flow Applications for PDC Products View Level Applications for PDC Products View Pressure Applications for PDC Products View Temperature Applications for PDC Products PDC Footer