Precision Digital ISO 9001:2000 Certified Quality System Go to Precision Digital Homepage Shop Online
What's New at Precision Digital News from Precision Digital Rate/Totalizers, Fluidwell, NOVA Rate/Totalizers, Fluidwell, NOVA Precision Digital Pricelists Precision Digital Services Precision Digital Support Services Instrumentation Design & Sales JobsContact Precision Digital CorporationView Precision Digital Videos
PD675-677 LOOP-POWERED NEMA 4X METER
   
   
 

Key Features Setup Disassembly Connections

Calibration Specifications Ordering Information Documentation

LOOP-POWERED NEMA 4X METER


Model PD675 NEMA 4X

Model PD677 Explosion-Proof

Loop powered Meters: PD675  NEMA 4X Loop Powered Meters: PD677 Explosion Proof

  •  4½ Digit 0.7" (17.8 mm) LCD, 19999
  •  FM Approved & CSA Certified
  •  Impact-resistant polycarbonate body
  •  Operates from -20 to 65°C
  •  Easy to Calibrate

Note: For complete installation information see instruction manuals below
  •  4½ Digit 0.7" (17.8 mm) LCD, 19999
  •  PD677-N-EX is FM Approved & CSA Certified
  •  Ex-proof, cast aluminum with glass window
  •  Operates from -20 to 65°C
  •  Easy to Calibrate
FM Approved Loop-powered indicator      CSA Certified Loop Powered Indicator


Use these 4-1/2 digit Loop-powered meters to display numbers up to 19,999 with 1 count resolution. That is, they will display numbers like 7124, 15697 or 124.78 as "whole numbers" -- no dummy zeroes or multipliers needed! These new meters are also available in 3 enclosure types: Panel mount, NEMA 4X, and Explosion-proof so they can be located almost anywhere in the plant. Options include open collector high-level-alarm output and square root extraction. The PD675-N and PD677 have been FM and CSA Certified approved as explosion-proof as complete products- not just the enclosures.

Setup


The only tools needed for calibration are a calibrated current source, a flat head screwdriver & a phillips head screwdriver. Please note that the meter must be disassembled in order to perform the setup functions.

Disassembly


The calibration controls are located behind the display faceplate. To access these controls, you must first remove the enclosure cover and faceplate by doing the following:

PD675: Loosen the four screws on the enclosure cover and remove. Unscrew the two fasteners that hold the faceplate, then remove.

PD677: Turn the enclosure cover counterclockwise to remove. Unscrew
the two fasteners that hold the faceplate, then remove.

Loop-Powered Meters Disassembly diagram


Figure 1. PD677 Assembly

Note: When reassembling boards DO NOT over-tighten screws.
Connections


Field connections are made to the screw terminals located on the Signal Input Board. To access these screw terminals it is necessary to remove the Display Board from the Signal Input Board. First, disconnect the ribbon cable connector from the Display Board. Next, remove the two screws located to the left and right of the LCD that hold the Display Board in place. Finally, remove the Display Board carefully to avoid contact with any rough surfaces.

Loop-Powered Meters Connections Diagram

Figure 2. Signal Input Connections

Decimal Point Selection


Decimal point selection is accomplished using JP1 located behind the faceplate to the right of the display. Leave jumper on one pin only for a display of 19999 (default), place the jumper over both pins of #1 for a display of 1999.9, #2 for 199.99, #3 for 19.999, #4 for 1.9999

Loop-Powered Meters Jumpers
Calibration Controls


Calibration of these meters is a two-step process involving four controls. These controls are located on the Display Board. The LO controls are on the right and the HI controls on the left. The pre-configured jumper array
JP2 and JP3 are also located on the Display Board.

Calibration Procedures


Connect the 4-20 mA input signal. Apply 4 mA to the input and adjust the coarse and fine LO controls for the desired reading. Next apply a signal between 16 and 20 mA and adjust the coarse and fine HI controls for the desired reading. Complete the calibration by making any minor adjustments to the LO and HI displays.

Jumper positions
Loop-Powered Meters Jumpers Positions

Figure 3. Display Board
Balance Potentiometer (R24) is preset at the factory
 
Mounting Kits
PD675 Panel Mount
PDA6844 Panel Mounting Kit

PDA6844 Panel Mounting Kit
PD675-677 Pipe Mounting Kits
PDA6845 Pipe Mounting Kit

PDA6845 Pipe Mounting Kit
PDA6845 Pipe Mounting Kit

Mounting Plate Hole Pattern
 
Mounting
PD675
Loop-Powered Meter PD675 Mounting Dimensions


A: 3.15 (80) E: 2.56 (65)
B: 5.51 (140)F: 0.79 (20)
C: 2.36 (60) 
D: 4.72 (120) 


PD677

Loop-Powered Meter PD677 Mounting Dimensions
A: 5.44 (138)B: 5.63 (143)
C: 4.06 (103)D: 5.63 (143)


Specifications

General
Input: 4-20 mA @ 24 VDC maximum
Accuracy: ±0.05% FS ±2 counts
Decimal Point: User selectable
Calibration Range: 4 mA input: -5000 to +5000;
20 mA input: between 200 and 20000 above 4 mA input
Maximum Voltage Drop: 5.2 VDC @ 20 mA
Display Update Rate: 2.5/second
Operating Temperature: -20 to 65°C
Storage Temperature: -40 to 80°C
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminals accept 12 to 22 AWG
Warranty: 2 years parts & labor
Extended Warranty: 1 or 2 years, refer to Price List for details.

PD675
Display: 0.7" (17.8 mm) LCD, 4½ digits; 19999
Approvals: FM Approved & CSA Certified as non-incendive for Class I, Division 2, Groups A, B, C, & D; suitable for Class II, Division 2, Groups F & G; suitable for Class III, Division 2, indoor and outdoor, hazardous (classified) NEMA 4X locations.
Enclosure: Impact-resistant polycarbonate body, color: gray; clear polycarbonate cover; NEMA 4X, IP67. ½" conduit hole provided at base.
Weight: 12 oz (340 g)

PD677
Display: 0.7" (17.8 mm) LCD, 4½ digits; 19999
Approvals: The PD677-N-EX is FM Approved & CSA Certified as explosion-proof for Class I, Division 1, Groups B, C, & D; dustignition proof for Class II, Division 1, Groups E, F, & G, Class III hazardous (classified) locations.
Enclosure: Explosion-proof, cast aluminum with glass window, 0.3% max copper content, corrosion resistant polyester powder coating, color: safety blue. NEMA 4X, 7, & 9, IP66; FM Approved & UL/C-UL Certified: Class I, Division 1, Groups B, C, & D, Class II, Groups E, F, & G, Class III; Class I, Zone 1 AEx d IIC hazardous outdoor (Type 4X) locations. IEC rating: Ex d IIC IEC 60529 IP66. Two ¾" NPT holes provided.
Weight: 5.7 lb (2.6 kg)


Disclaimer

The Information contained in this document is subject to change without notice. Precision Digital Corporation makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose.

ORDERING INFORMATION

Products
Model Description Price
PD675-N        FM Approved & CSA Certified Loop-Powered NEMA 4X Meter        $369.00
PD677-N        Explosion-Proof Loop-Powered Meter        $569.00
PD677-N-EX        FM Approved & CSA Certified Explosion-Proof Loop-Powered Meter        $619.00
  
Accessories
Model Description Price
 PDA6845        Zinc Plated Pipe Mounting Kit with 2 Holes        $49.00
 PDA6845-SS        Stainless Steel Pipe Mounting Kit with 2 Holes        $79.00
 PDA-SSTAG        Stainless Steel Tag        $25.00
 PDA6844        Panel Mounting Kit for PD675, PD685, PD686 and PD697        $49.00


 
Documentation
The documentation can be downloaded from these links:
PD675-677: Instruction Manual
Mounting Kits for Precision Digital Meters
Setup and Calibration Services Order Form
Stainless Steel Tag Order Form

See How You can Use Precision Digital Products for
View Flow Level, Pressure and Temperature Applications
 What's New | News | Products | Pricelist | Services | Support | Jobs | Contact Us | Site Map
Precision Digital: Distributors and Manufacturers of Digital Panel Meters and Indicators
View Flow Applications for PDC Products View Level Applications for PDC Products View Pressure Applications for PDC Products View Temperature Applications for PDC Products PDC Footer